Start XP system Press F1 to enter 13 tips

Source: Internet
Author: User
Tags reset

1, reboot the system, into the BIOS setup, found that the floppy drive is set to 1.44M, but in fact there is no floppy drive in the chassis, this is set to none, troubleshooting.

A lot of people have asked this question, the following will I have encountered such issues to do a summary, I hope to help.

2. Hareware Monitor found a error,enter power MANAGEMENT setup for details,press F1 to Continue,del to enter SETUP

Chinese: monitoring function found error, enter the power MANAGEMENT Setup to see the details, press F1 key to continue the boot process, press del key to enter COMs settings.

Explanation: Some motherboards have the hardware monitoring function, you can set the motherboard and CPU temperature monitoring, voltage regulator voltage output and monitor the speed of each fan, when

The above monitoring function in the boot when found that there are abnormal conditions, then this paragraph will appear, then you can enter the COMs settings select Power MANAGEMENT Setup, on the right side of the **fan monitor**, **thermal monitor** and * * Voltage monitor** to see which part of the issue was abnormal and then solve it.

3. pri slave drive-atapi lncompatible Press F1 to Resume

It may be that your optical drive is not properly connected or faulty, preferably in CMOS, the IDE ports are set to automatic.

4, CPU has been changed please re-enter CPU settings in the CMOS setup and remember to save before

Some motherboards have a FSB jumper, the default is 100MHZ, and some motherboards do not support automatic FM. All you have to do is go into the BIOS and set the FSB to your CPU standard FSB, the frequency multiplier is usually automatic setting, it is best not to overclocking.

5. Press F1 to Continue,del to enter SETUP

Press Del to enter the BIOS after boot, select NONE in the floppy drive and press F10 to save it.

6, CMOS checksum error-defaults loaded

Press F1 to Contnue? DEL to enter SETUP

08/09/2000-i810-ite8712-6a69me1cc-00

The CMOS battery is out of power.

7. Try not to install the floppy disk drive, but you set the option in CMOS if the floppy drive is turned on.

The method is: Boot press del key, enter the BIOS setting, choose the first "basic setting", put floopy a set not "Disabel" invalid on it.

8. Just start to press the Del into the BIOS, press ENTER to enter the first item, see inside the "Drive A" item is not "None", not the words "PgUp" or "PgDn" to modify, after the modified press "ESC" exit, select "Save & Exit Setup" Items press ENTER to exit the BIOS, reboot, no longer can not be changed the battery and then press the steps above to reset both.

9. The boot needs to press the F1 key to enter, mainly because the BIOS settings and real hardware data does not match, can be divided into the following situations:

10, actually do not have a floppy drive or floppy drive is broken, and the BIOS is set up with a floppy drive, which causes to press F1 to continue.

11, the original hung two hard disk, in the BIOS set into a dual hard drive, and then took off one of the time but forgot to change the BIOS settings, it will also appear this problem.

12, the motherboard battery does not have electricity also can cause the data to lose thereby to appear this fault.

13, warning! CPU has been changed! Please Enter the CPU speed CMOS setup and Remember to save before exit!

This indicates that the BIOS settings have been flushed out and that the BIOS (also known as the CMOS setting) should be reset. Power on the "Del" key to enter the settings, see your motherboard instructions. What is your CPU frequency? In the BIOS to choose a good FSB, the frequency multiplier is locked anyway. FSB is always 66, 100, or 133, looking at the CPU model, setting from low to high. If you are award BIOS setup, select Frequency/voltage Control (frequency/voltage controls) on the home page and use this menu to set the frequency and voltage specifically. Where "Clock by slight Adjust (clock frequency fine-tuning)" Allows you to choose the CPU clock frequency.

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.