SYN5301 Type Time Verification device

Source: Internet
Author: User

SYN5301 type Time Verification Device

Fixture overview

Our fixture can be placed horizontally measured stopwatch, but also vertical measurement of the stopwatch, and other manufacturers of fixtures can only be measured horizontally, if you want to vertical measurement to rely on the wall or other objects to test, so that the detected data will have a certain deviation, and their fixture rough, 2, other manufacturers of fixtures can only test 1 blocks, While our fixture can measure multiple stopwatch at the same time, this will greatly save time, moreover, our fixture work more delicate, more in line with the stopwatch verification procedures.

Product introduction

The SYN5301 type time verification device is a high precision time calibrator. This equipment is based on the requirements of jjg237-2010 "stopwatch verification procedures" of a multifunctional, comprehensive time verification automatic testing device for the verification of mechanical stopwatch, electronic stopwatch, pointer-type electric stopwatch, digital electric stopwatch, digital millisecond meter, and various timers, etc. Measured by measuring the standard time interval signal, the instrument is measured by measuring the measured value of the standard time interval signal, so as to obtain the measurement error of the instrument, to achieve the purpose of verification, suitable for various types of stopwatch of the value of transmission, can establish a stopwatch calibration standard device, to carry out time-class instruments for verification/calibration.

Product Features

Can be used at all levels of measurement departments, factories, institutions and scientific research units 401/405 electric stopwatch, 407/408 stopwatch, 411 digital millisecond meter, 415/417/417b type digital stopwatch and other time-class instruments

Product Features

A) high precision, cost-effective;

b) Full-featured, reliable performance;

c) The use of high-stability quartz crystal oscillator as a time reference.

Time Verification Device

Typical applications

1) for the measurement departments at all levels, factories, colleges and scientific research units on mechanical stopwatch, electronic stopwatch, pointer-type electric stopwatch, digital stopwatch, digital millisecond meter and other timing instruments for verification.

2) used as the daily difference measuring instrument;

3) used as a standard time interval generator;

Technical Index

Mechanical stopwatch and electronic stopwatch

Input Time range

300MS~9 999 999 999s

Accuracy

Better than ± (1X10-7XT0+3MS)

Physical interface

Banana seat

Pointer-type electric stopwatch

Input Time range

0.02S ~ 9 999 999 999s

Accuracy

Better than ± (mains frequency accuracy xt0+0.6ms)

Physical interface

Banana seat

Stopwatch and Digital Electric stopwatch

Input Time range

0.01μs ~ 9 999 999 999s

Accuracy

Better than ± (1x10-7xt0+1μs)

Physical interface

BNC

Crystal Oscillator Index

Frequency

10MHz

Daily aging Rate

≤5x10-9/Day

Second degree of stability

≤5x10-11/s

Accuracy

≤1x10-7

Warm-up time

12 hours

50Hz

Large ones

1

Level

Ttl

Physical interface

DB9

10MHz

Large ones

1

Level

≥7dbm

Physical interface

BNC

RS232C Serial Port

Large ones

1-Way

Level

rs232c

Physical interface

DB9

Stopwatch Fixture

Test four stopwatch at a time to adapt to various shapes of stopwatch

Environmental characteristics

Operating temperature

0℃~+50℃

Relative humidity

≤90% (40 ℃)

Storage temperature

-30℃~+70℃

Power supply

AC 220V±10%, 50hz±5%, power less than 30W

Chassis dimensions

3u,19″ standard Chassis (upper frame) 482mm (w) x300 (deep) x140mm (h)

Options

Custom-made similar products according to customer requirements.

classification of mechanical stopwatch

1 Press the second hand to beat the amount divided into: 1% (0.01) seconds, One-fiftieth (0.02) seconds, One-tenth (0.1) seconds and one-fifth (0.2) seconds four kinds. 2 The number of seconds is divided into two types: application and double needle. The two-pin stopwatch secondary seconds stop should not be related to the primary hand, and after the stopwatch is stopped, the secondary second hand can not be reversed to 0 and coincide with the main second hand.

3 According to the second hand action situation is divided into: simple action and comprehensive action two.  The former must be returned to 0 after the pointer has stopped, and the latter can start moving at any position where the pointer stops. 4 According to the minute hand action situation is divided into: instantaneous action and semi-instantaneous action two kinds.  The minute hand of the former rotates continuously with the second's stroke, and the latter only beats once at a certain value. 5 According to the structure is divided into: continuous action and discontinuous action of two. The former does not interrupt the rotation of the balance wheel when the second hand starts and stops, and the second hand starts and stops as a result of the wheel's push or braking action. In addition to this, some stopwatch dials can be rotated, the dial can be rotated to 0.

Part of the verification procedures:

First, technical requirements

The 1-second table is divided into one and tertiary according to the accuracy level, and its accuracy index

(The average correction value C and the allowable maximum deviation for each of the corresponding locations allowed) should not be greater than the values listed in table 1.

2 seconds after the watch is fully wound, the duration should be no less than the schedule.

The 3 second table must have the manufacturer's name and number.

Ii. Conditions of verification

4-Ring condition

4.1 Ambient temperature: 20±5℃.

4.2 Relative Humidity: 80% or less.

The 4.3-second table must be placed in the verification environment for more than one hour before verification.

5 Standard equipment

Any of the following standard equipment may be used for verification purposes (but no mechanical stopwatch is allowed for the calibration of mechanical stopwatch).

5.1 Second meter calibration device. The basic error does not exceed ±10ms.

5.2 Standard precision clocks. The daily difference does not exceed ±4s.

5.3 Quartz clock. The second hand beats at 1/2s or 1s, and can hear a clear seconds beat, and the accuracy of the crystal oscillator is better than 2x10-5.

6 check interval is the second dial and the full value of the sub-scale (such as the use of the stopwatch has special requirements, can be negotiated with the verification unit to resolve).

7 verification shall be carried out within the specified clockwork effective working time

Time Verification Device

Contact information: 1⑧⑨⑨1⑨3⑦⑥18

Q : 25③④②④0205

Website: www.syn029.com

Contact person: well-off

SYN5301 Type Time Verification device

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.