I. Managing redundant network settings

1. Select ESXi Host, select 192.168.1.21, and on the right "Configuration" tab select "Network" of "Hardware", select "vSwitch0" Switch "Properties"

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image001 "border=" 0 "alt=" clip_image001 "src=" http://s3.51cto.com/wyfs02/M00/58/3F/ Wkiol1ss8ubgje3baaivn2mu6aq507.jpg "" 649 "height=" 480 "/>

2. In the VSwitch0 Properties dialog box, select Network adapter

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image002 "border=" 0 "alt=" clip_image002 "src=" http://s3.51cto.com/wyfs02/M01/58/3F/ Wkiol1ss8ufj1bpdaaexzhexlwy011.jpg "" 514 "height=" 378 "/>

3. Select "Add" to add a physical NIC

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image003 "border=" 0 "alt=" clip_image003 "src=" http://s3.51cto.com/wyfs02/M02/58/3F/ Wkiol1ss8ufretowaaeokfuqeus851.jpg "" 553 "height=" 407 "/>

4. Select a piece and vmnic0 in the same network segment or trunk of the physical network card, this example select Vmnic3, and vmnic0 in the same network segment, 192.168.1.0 network segment

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image004 "border=" 0 "alt=" clip_image004 "src=" http://s3.51cto.com/wyfs02/M00/58/3F/ Wkiol1ss8ujhqvwtaagjaf8jiks897.jpg "" 559 "height=" 510 "/>

5. Set the failover sequence for the Vswitch Standard and management network management networks, and place the Vmnic0 and Vmnic1 in the active adapters group, respectively

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image005 "border=" 0 "alt=" clip_image005 "src=" http://s3.51cto.com/wyfs02/M01/58/3F/ Wkiol1ss8umh2kszaahdu-r8foi474.jpg "" 568 "height=" 519 "/>

6. Display "Adapter Summary" information, select "Finish" to complete the add NIC process

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image006 "border=" 0 "alt=" clip_image006 "src=" http://s3.51cto.com/wyfs02/M02/58/3F/ Wkiol1ss8uqb8lqfaadzkytpvz0553.jpg "" 578 "height=" 528 "/>

7. Finish adding the physical NIC, select "Off"

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image007 "border=" 0 "alt=" clip_image007 "src=" http://s3.51cto.com/wyfs02/M02/58/3F/ Wkiol1ss8urb-qfwaafjexwoeho152.jpg "" "height=" 441 "/>

8. Complete the physical NIC add

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image008 "border=" 0 "alt=" clip_image008 "src=" http://s3.51cto.com/wyfs02/M00/58/43/ Wkiom1ss8ivym5mnaahxwmrpb_k057.jpg "" 602 "height=" 445 "/>

Second, virtual standard switch and virtual machine Port Group property settings

1. In the properties of the VSwitch0 virtual standard switch, in the Christmas box, select "VSwitch" and select "Edit"

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image009 "border=" 0 "alt=" clip_image009 "src=" http://s3.51cto.com/wyfs02/M01/58/43/ Wkiom1ss8ivbli70aaf07vkclj4423.jpg "" 611 "height=" 449 "/>

2. Select the "General" tab, you can set the standard switch "number of ports", the default 120, you can set the MTU value, the default is 1500, if the virtual standard switch for iSCSI, the recommended MTU set to "9000"

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image010 "border=" 0 "alt=" clip_image010 "src=" http://s3.51cto.com/wyfs02/M02/58/43/ Wkiom1ss8iyhj_izaadnid5kano091.jpg "" 476 "height=" 588 "/>

3. On the "Security" tab, set the network security policy

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image011 "border=" 0 "alt=" clip_image011 "src=" http://s3.51cto.com/wyfs02/M00/58/3F/ Wkiol1ss8u7hlxmvaajcfpd1qm0302.jpg "" 607 "height=" 314 "/>

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image012 "border=" 0 "alt=" clip_image012 "src=" http://s3.51cto.com/wyfs02/M00/58/43/ Wkiom1ss8i6s27i6aadtu_zahy0111.jpg "" 470 "height=" 581 "/>

4. In the Traffic Adjustment tab, set the traffic shaping policy

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image013 "border=" 0 "alt=" clip_image013 "src=" http://s3.51cto.com/wyfs02/M01/58/3F/ Wkiol1ss8u-ap9anaaktklpndug526.jpg "" 743 "height=" 278 "/>

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image014 "border=" 0 "alt=" clip_image014 "src=" http://s3.51cto.com/wyfs02/M02/58/3F/ Wkiol1ss8vdzppflaadrgocyvmi563.jpg "" 390 "height=" 482 "/>

5. On the "NIC Bindings" tab, set the physical NIC load policy and switch policy

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image015 "border=" 0 "alt=" clip_image015 "src=" http://s3.51cto.com/wyfs02/M00/58/3F/ Wkiol1ss8vdd7qkraaehrnqwx2i990.jpg "" 678 "height=" 184 "/>

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image016 "border=" 0 "alt=" clip_image016 "src=" http://s3.51cto.com/wyfs02/M01/58/3F/ Wkiol1ss8vgryavwaagrqkg1gnu146.jpg "" 679 "height=" 198 "/>

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image017 "border=" 0 "alt=" clip_image017 "src=" http://s3.51cto.com/wyfs02/M02/58/3F/ Wkiol1ss8vlrh81baag1zjoinec197.jpg "" 687 "height=" 223 "/>

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image018 "border=" 0 "alt=" clip_image018 "src=" http://s3.51cto.com/wyfs02/M01/58/3F/ Wkiol1ss8vkzzineaadnbaz97k8459.jpg "" 695 "height=" 131 "/>

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image019 "border=" 0 "alt=" clip_image019 "src=" http://s3.51cto.com/wyfs02/M01/58/43/ Wkiom1ss8jlc9125aagwukwwf9u133.jpg "" 459 "height=" 567 "/>

6. Select "VM Manager Network" to manage the virtual machine port Group of the networks, select "Edit"

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image020 "border=" 0 "alt=" clip_image020 "src=" http://s3.51cto.com/wyfs02/M00/58/43/ Wkiom1ss8jozs2xoaaela7r9xqw558.jpg "" 520 "height=" 382 "/>

15. In the "Network Tag", enter the name of the network tag you want, if VLAN is required, enter "VLAN ID", but also need to set the port of physical switch connected to the physical network card into trunk mode

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image021 "border=" 0 "alt=" clip_image021 "src=" http://s3.51cto.com/wyfs02/M01/58/43/ Wkiom1ss8jsj4sxyaaddluimmye496.jpg "" 481 "height=" 594 "/>

16. Individually adjust the network security policy as needed, inheriting the configuration of the virtual switch "VSwitch0" by default.

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image022 "border=" 0 "alt=" clip_image022 "src=" http://s3.51cto.com/wyfs02/M02/58/43/ Wkiom1ss8jtxqgrqaadf-hc2doi599.jpg "" 476 "height=" 588 "/>

17. If you need to adjust the traffic to the Management network, the configuration of the virtual standard switch (VSWITCH0) is inherited by default

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image023 "border=" 0 "alt=" clip_image023 "src=" http://s3.51cto.com/wyfs02/M00/58/43/ Wkiom1ss8jwwrthgaaetueqr4hq070.jpg "" 475 "height=" 587 "/>

18. If required, you can adjust the physical network bindings and load balancing policies for the virtual machine Port group that manages the network, inheriting the configuration of the virtual standard switch (vSwitch0) by default

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image024 "border=" 0 "alt=" clip_image024 "src=" http://s3.51cto.com/wyfs02/M01/58/43/ Wkiom1ss8jawj7_7aagvhq39gm4107.jpg "" 474 "height=" 585 "/>

19. Select "Management Network" Vmkernel Port

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image025 "border=" 0 "alt=" clip_image025 "src=" http://s3.51cto.com/wyfs02/M02/58/43/ Wkiom1ss8jehwp6maaeli7ep8fw315.jpg "" 494 "height=" 363 "/>

20. In the Vmkernel for management, tick "manage traffic", if VLAN is required, enter the VLAN ID, if you need to open the jumbo frame package, adjust the "MTU" value to 9000

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image026 "border=" 0 "alt=" clip_image026 "src=" http://s3.51cto.com/wyfs02/M00/58/43/ Wkiom1ss8jfcw9cvaaec-ani4oa222.jpg "" 435 "height=" 537 "/>

21. Set the administrative address of the ESXi host

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image027 "border=" 0 "alt=" clip_image027 "src=" http://s3.51cto.com/wyfs02/M00/58/40/ Wkiol1ss8vigrzyqaadjq-lywfg385.jpg "" 444 "height=" 548 "/>

22. Adjust the network security policy as needed, using the policy of the virtual standard switch by default

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image028 "border=" 0 "alt=" clip_image028 "src=" http://s3.51cto.com/wyfs02/M02/58/40/ Wkiol1ss8vmau1emaadpb_rcrk4452.jpg "" 448 "height=" 553 "/>

23. Adjust network traffic as needed

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image029 "border=" 0 "alt=" clip_image029 "src=" http://s3.51cto.com/wyfs02/M00/58/40/ Wkiol1ss8vqh_c_caaekupz07g4798.jpg "" 446 "height=" 551 "/>

24. Adjust the network card bindings and load balancing policies for the vmkernel of management networks as needed

650) this.width=650; "Style=" border-bottom:0px; border-left:0px; border-top:0px; border-right:0px "title=" clip_image030 "border=" 0 "alt=" clip_image030 "src=" http://s3.51cto.com/wyfs02/M01/58/40/ Wkiol1ss8vrhaybgaagxbxyo5oa393.jpg "" "height=" 556 "/>

VMware VSphere VCenter 5.1 's management Network and security settings

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.