Zabbix monitoring of Dell's Idrac via SNMP
The original is from the Zabbix forum, the improved version from the post-attached GitHub address, Local is the finished version, added value mapping content, has been updated as a readme to the author.
Please check the attachment [Template_dell_idrac_snmpv2.zip], or go to Gitlab to download the template.
menu: administration->general->value mapping->create value mapconfiguration of value mappingnotice: 1)  USE TEMPLATE_DELL_IDRAC_SNMPV2.ZBX.XML2) website: https://github.com/endersonmaia/zabbix-templates/tree/master/dell/idracadd k/v (s) as Given below:--------------------------delldracdiskstate1 -> unknown2 -> ready3 -> Online4 -> Foreign5 -> Offline6 -> Blocked7 -> Failed8 -> Non-RAID9 -> RemovedDell iDRAC Network Device connection status1 -> down2 -> updell open manage system status1 -> other2 -> unknown3 -> ok4 -> noncritical5 -> critical6 -> nonrecoverabledellpowerstate1 -> other2 -> Unknown3 -> oFf4 -> ondell psu state settings1 -> unknown2 -> online (state disabled) 4 -> not ready8 -> fan failure10 -> Online and Fan Failure16 -> On242 -> Online and okdellraidlevel1 -> unknown2 -> raid-03 -> raid-14 -> raid-55 -> raid-66 -> raid-107 -> raid-508 -> raid-609 -> Concatenated RAID 110 -> Concatenated RAID 5dellraidvolumestate1 -> unknown2 -> online3 -> failed4 -> degradeddell_psu_sensorstate1 -> presence detected2 -> ps failure4 -> predictuve failure8 -> ps ac lost16 -> ac lost or out of range32 ->&nbsP Ac out of range but still present--------------------------
Zabbix monitoring of Dell's Idrac via SNMP