1 cabling standard for copper-cable twisted pair Line 6
Integrated wiring copper twisted pair Line 6 line standard has been formally introduced. With the rapid development of computer technology, people's demand for fast communication has increased the requirement of high transmission rate of broadband belt, and the bandwidth of the integrated cabling system is increasing continuously as the communication p
The cat6 cabling standard should be well understood by cabling personnel and its development is extremely rapid. This article will provide a detailed answer to this standard, I hope you will have a better understanding of the cat6 Cabling Standards.
Development of cat6 Cabling
In the early stage of operation, managers generally stick to the luck of "connecting" and do not pay much attention to the cabling of the data center. As a result, network connection errors are frequently caused, which may also affect energy consumption and heat dissipation, they still don't know why.
With the release of the network transmission standard 10 Gbit/s-T for 100-meter channel transmission. Internationally recognized
The test standard for cat6 cabling was officially released on April 9, June 20. The standard is ANSI/TIA/EIA568B. The standard consists of three parts: B .1-general, B .2-twisted pair wires, and B .3-optical cable. After nearly five years of discussion, the standard has been published more than 10 times, and is now officially promulgated. Soon after May), the European ISO
2004, the Working Group 802.3an was formally established, the draft 10GBASE-T the same year in June with a first draft, the official version is expected to be announced in 2006. At the June 2004 meeting, the Working Group revised the PHY encoding from PAM5 to PAM8, and the bandwidth requirements for Class E-level cabling systems were modified to 500MHz accordingly.
By contrast, TIA TR-42 is developing
military level, followed by industrial level, and the lowest level for commercial use.
In the Integrated Wiring System products, there have been products specifically designed for harsh environments, which are referred to as industrial-level cabling systems in standards. They have the ability to defend against various harsh environments, such as strong electromagnetic fields, oil stains, water, dust, and s
Medical industry in the integrated wiring is a relatively special user. Compared with other business users, the medical profession, especially the large hospitals, needs to consider more aspects when building. For example, in the hospital, when the start of the construction of the need to consider a good enough channel and space, so that in the future when demand changes can be expanded according to need. Especially in the need to isolate the environment, if you want to add a wall to go through
Design Standards: IEEE802 standard and 100BASE-TX Standard
EIA/TIA568 industrial standards and international business building wiring standards
Ansi fddi/TPDDI 100 Mbps
Ccitt atm 155 Mbps/622 Mbps
Installation and design specifications: China building electrical design code
Industrial Enterprise Communication Design Specifications
General principles of Stru
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.