Since the closed cooling tower in the factory has been assembled, then when shipped to the scene to install the diamond closed cooling tower manufacturers give the following suggestions to facilitate the construction of reference. At the same time can also avoid due to site construction errors caused by many problems. Pay attention to every detail of the correct, each aspect of the basic configuration in order to make the closed tower in the later use of the process to reduce maintenance times.
Tip One, piping needs to be grasped
Closed-type cooling tower in the project may be in the final stage of installation, and in the prior to the required pipeline layout completed, and closed-type cooling tower manufacturers are advised in the pre-construction period should refer to the cooling tower inlet and outlet pipe size and pipeline parallel and series of the direction of the problem, due to the pressure and flow of water pump, closed cooling tower treatment , the pipeline is also an important part in the whole design to ensure the cooling efficiency of the closed tower.
Tip Two, take care of the problem
Closed-type cooling tower manufacturers are advised to pay attention to ensure that the water pipe and cooling tower of the balance of the interface, and the support frame as a fixed use, when the water pipe once filled with a certain gravity to make the water pipe down, over time may cause the closed cooling tower to crack and leakage, and in the late maintenance, The inadvertent trampling of a person can also cause a leak at the receiver. Once experienced by the takeover operation is not standardized and in the use of six months of cracking leakage, in this case, closed cooling tower manufacturers after-sales maintenance also increased a lot of difficulties. So the takeover must be in accordance with the norms of operation, do not promote the province of the attitude of the province.
Tip three, reasonable choice of soft connector
In the closed cooling tower joint selection, closed-type cooling tower manufacturers do not agree with the installation of a violent installation, the use of a reasonable choice of soft connectors to connect, the benefits of soft connection is the expansion of the joints, can avoid a lot of violent takeover caused by leakage leakage phenomenon, but also the most convenient way to take over.
Tip Four, piping installation valve
The installation of the valve can be more convenient to the closed cooling tower overhaul, but also facilitate the operation of the late, and in the winter can be quickly emptied so that the external circulation using no-load heat dissipation, and closed-type cooling tower manufacturers also favor the installation of modular valves, easy to use more easily.
Closed-type cooling tower manufacturers reasonable use of software and valves can reduce unnecessary trouble in the late
Closed-type cooling tower manufacturers reasonable use of software and valves can reduce unnecessary trouble in the late
Closed cooling tower slowly into the daily life and production, and gradually play its important function of energy saving and emission reduction, in fact, many users now in the use of the time, and did not pay attention to these settings problems, and Ling Ke closed cooling tower manufacturers through simple guidance, so that the energy consumption greatly reduced, Make the cooling tower more practical by making the operation more convenient.