ORA-01281: SCN range specified is invalid Error

Source: Internet
Author: User

When configuring Streams, if the streams process is configured first, users who do not need to transmit data are prone to ORA-01281: SCN range specified is invalid

Select * from dba_capture

We can see that

ORA-01281: SCN range specified is invalid

This is because the process of two-way database transmission is configured, and no database transmission user has been created. All reports that the scn is out of the range.

You can delete the Streams process on both ends of the database and reconfigure the process to solve the problem above.

Exec dbms_capture_adm.drop_capture ('capture _ stream ')

Exec dbms_propagation_adm.drop_propagation ('source _ TO_TARGET ')

Exec dbms_apply_adm.drop_apply ('target _ APPLY_STREAM ')

Related Article

Contact Us

The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion; products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the content of the page makes you feel confusing, please write us an email, we will handle the problem within 5 days after receiving your email.

If you find any instances of plagiarism from the community, please send an email to: info-contact@alibabacloud.com and provide relevant evidence. A staff member will contact you within 5 working days.

A Free Trial That Lets You Build Big!

Start building with 50+ products and up to 12 months usage for Elastic Compute Service

  • Sales Support

    1 on 1 presale consultation

  • After-Sales Support

    24/7 Technical Support 6 Free Tickets per Quarter Faster Response

  • Alibaba Cloud offers highly flexible support services tailored to meet your exact needs.