Here are the steps to import a foreign hard drive into an array card, please do so when you are sure the data is backed up, and only provide references .
Today, the Dell 720 system fails to boot up the monitor to see if there is a problem with the raid;
1. Start the boot by pressing "ctrl+r" to enter the raid settings.
2. enter PD Mgmt to view the status of the failed disk (foreign: foreign, Online: normal, missing: Disk not found, failed: failed)
3. If the disk status is foreign, under the VD Mgmt interface, move the indicator to the top row, press F2, and select Import under Foreign config.
attention!!! You must never use the Clear Config
650) this.width=650; "src=" Http://s2.51cto.com/wyfs02/M02/7E/A2/wKiom1cF272R8Ee6AAD9HU2TcEE642.png "title=" Cccc.png "alt=" Wkiom1cf272r8ee6aad9hu2tcee642.png "/>
4. Follow the above operation, save and restart the server, the system can be started.
The status of the Dell server hard disk becomes foreign (foreign)