Recently, a project of jquery upgraded to the latest version, found some pages error cannot read property ' Msie ' of undefined. On the jquery site search, the reason is $.browser this API from the beginning of jQuery1.9 formally abolished, JS code as long as the use of $.browser will report this error. See the official jquery note for details.The landlord by the way expand read a bit, found jquery The version after 1.9 has officially removed all APIs
Using Ztree when not using the default 1.4 version of jquery, error cannot read property ' Msie ' of undefined $.browser This API from the beginning of jQuery1.9 formally abolished, JS code used to $.browser will report this error. See the official note for more information Workaround Add the following code before the jquery file is loaded, using the $.browser code. jquery.browser={};(function () {jquery.browser.msie=false; Jquery.browser.version=0
. Web Browser control–specifying the IE VersionHttp://www.west-wind.com/weblog/posts/2011/May/21/Web-Browser-Control-Specifying-the-IE-VersionI Use the Internet Explorer Web Browser Control in a lot of my applications to display document type layout. HTML happens to is one of the most common document formats and displaying data in this format–even in desktop Applicatio NS, is often-easier than using normal desktop technologies.One issue the Web Browser Control has this it ' s perpetually stuck i
Because the diagram is convenient, copied someone else wrote a Jquerry plug-in, run-time "var pos = ($.browser.msie parseint ($.browser.version) Search the Internet, http://stackoverflow.com/questions/14923301/. Uncaught-typeerror-cannot-read-property-msie-of-undefined-jquery-tools said that after jquerry1.9, the browser attribute has been removed. On the Jquerry official website looked up the API, indeed has been removed. The official website recomm
Microsoft last year released the MSIE DHTML Edit Control cross-site Scripting vulnerability, but the circle has not been published to use exp, harm a bunch of novice frustrated, don't worry, this is not for everyone sent a feast?!
[Affected Systems]
Microsoft Internet Explorer 6.0
-Microsoft Windows XP Professional SP1
-Microsoft Windows XP Professional
-Microsoft Windows XP Home SP1
-Microsoft Windows XP Home
-Microsoft Windows ME
-Microsoft Windows
Initial use of Yii's Srbac module. Cannot read property ' MSIE ' of undefined error appears. Online Search, find the following article. Using the method of patching at the end of the text, successful. Thank.===============================http://blchen.com/jquery-can-not-read-property-msie-of-the-undefined-error-solution/Recently, a project of jquery upgraded to the latest version, found some pages error can
today, when I was doing angular's project, Because need to use ui-select2 so introduced Bootstrap.js, and then bootstrap.js need jquery1.9 version above, so simply replaced a 2 version, the result of dialog failure not to say, also appeared cannot read Property ' Msie ' of undefined error, so in the online check for a reason, probably upgrade to JQ2 version of the compatibility problem, the solution altogether two kinds:(1) The introduction of jquery
JQuery cannot read property ' MSIE ' of undefined error resolution
Recently upgraded a project jquery to the latest version and found that some pages reported the following error
Cannot read property ' Msie ' of undefined
On the jquery site search, the reason is $.browser this API from the beginning of the jQuery1.9 formally abolished, JS code as long as the use of $.browser will report this error. Refer
The best way:
Let's say something basic:
CODEPAGE specifies what IIS encodes to read the string passed over (form submission, address bar delivery, etc.).
The reason for the garbled is that the site should be integrated when the module coding is not the same.
As my blog is the same, the integration of the time will be the problem, because the blog is Utf-8,
Recently many netizens are consulting for this problem, I have tried many ways.
The most conv
The best method:
Let's talk about the basic things:
CodePage specifies the encoding used by IIS to read passed strings (such as form submission and address bar transfer ).
The cause of garbled characters is that the module encoding is different when the website is to be integrated.Like my blog, this problem occurs during integration, because the blog is Utf-8,Recently, many netizens have been asking for this question. I have tried many methods.Th
_ {21} e _ {1}-A _ {12} e _ {2} \ right) = 0 \\\ rightarrow A _ {12} ^ 2 = A _ {21} ^ 2 \ EEA \ eeex $ and the two are different, so $ A _ {12} =-A _ {21} \ neq0 $. then, it must be $ A _ {1j} =-A _ {J1}, j = 3, \ cdots, N $, if $ A _ {1i} = A _ {I1} = 0 $, it is valid. therefore, you only need to consider the situation where $ J $ makes $ A _ {1j} \ neq0 $. then $ \ beex \ Bea 0 = E _ {1} ^ Tae _ {2}-\ frac {A _ {12} {A _ {1j} e _ {1} ^ Tae _ {J} \ = E _ {1} ^ ta \ left (E _ {2}-\ frac {A
Php page, mysql database to UTF-8 garbled, UTF-8 encoding problem summary, mysqlutf-8
Example 1:
PHP page to UTF-8 Encoding Problems
1. Add a line at the beginning of the Code: header ("Content-Type: text/html; charset = UTF-8 ");
2. PHP file encoding problem click Editor me
Rapidxml reading UTF-8 format xml garbled problem (UTF-8 format to GBK), rapidxmlutf-8
1. I use the rapidxml file to read xml in UTF-8 format, but garbled characters are displayed. We need to convert the read content to GBK format to display it normally.
Char * utf82gbk (char * strutf)
{
// Convert UTF-
Windows 8 and Windows Phone 8 tend to merge. At the same time, developers who are interested in building applications for these two platforms must understand the important similarities and differences between the two. Understanding the current common functionality of the Windows 8 and Windows Phone Runtime APIs gives you the opportunity to deliver applications to
http://blog.csdn.net/thl789/article/details/7506133Https://zhuanlan.zhihu.com/p/23654187?refer=dreawerHttp://www.ruanyifeng.com/blog/2007/10/ascii_unicode_and_utf-8.html
UTF-8UTF-8 (8-bit Unicode Transformation Format) is a variable-length character encoding for Unicode that encodes each character with one to four bytes:128 ASCII characters with a Unicode range
Pre-installed Win 8 standard version of the computer can also be a U disk boot New Installation win 8 Pro version, as long as the addition of ei.cfg can be. Last month to catch the Win 8 just launched when bought a new notebook computer, pre-installed "Win 8 Simplified Chinese version", and hard disk partition mess. So
BackgroundWindows Notepad will add BOM headers to the UTF-8 file, annoying, and get a generic read of the configuration file code."Config.ini"[Config] Srcroot=d:\inputdstroot=d:\output"T.py"#encoding =utf-8#author:walker#date:2018-03-31#summary: Read UTF-8/UTF-8-BOM Configuration file Importos,sysfromconfigparserimport
DOM4J cannot save the XML file as UTF-8, Invalid byte 2 of 2-byte UTF-8 Sequence-hxzon hands-gdo
These days began to learn dom4j, on the Internet to find an article on the dry, very fast, but found a problem is not to UTF-8 save the XML file, save again read out when will report "Invalid Byte 2 of 2-byte UTF-8 sequence
WIN8 RP Version finally released, it includes Simplified Chinese, Traditional Chinese and other multi-language version. This article for you to introduce the specific use of methods to facilitate the operation of everyone, the following a look at it.
1. Where is the "Start" button or "Start" menu?
In Windows 8, the Start screen replaces the Start menu. You can secure your applications, contacts, and Web sites to the start screen for easy access to
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.