The customer reported that the IBM P570 server was Down, and there was HACMP on the server. The address had been moved.
Fault Locating:
1. Run the HMC maintenance software on the IBM server to query the HMC management address on the server. This processing uses the IE Mode)
Use the <strong> or <strong> button of the Control Panel to select function 2.
Press <→> to enter function 2,
Press <→>, select N (Normal), and use the <strong> or <strong> button to change N to M (Manual)
2 times <→> exit function 2.
B. Use the <strong> or <strong> button to select function 30. Click <→>. Control Panel Display 30 **
C. Use the <strong> or <strong> button to display the Panel with 3000 or 3001, and then press <→> to read the IP address of the corresponding HMC port on the control panel. For example:
SP_A: _ ETH0: _ T5
192.168.2.147 ____
The IP address of port HMC0 is 192.168.2.147.
D. after the check is complete, use the <strong> or <strong> button of the Control Panel to select function 2. press <→> to enter function 2, click <→>, select N, and change M to N using the <strong> or <strong> buttons.
Then press twice <→> exit function 2
E. Select function 1 to enter the normal operation mode.
2. directly connect to the Ethernet control port. Enter https: // 192.168.2.147 for IE and enter the ASM management interface. The First Login will allow you to reset the password. The default value is admin/admin)
3. View Error/event Logs. (Most important to administrators)
Reference: 11001511
Hexadecimal 2-5: 003C0001 00000000 00000000 00000000
Hexadecimal 6-9: 00000000 00000000 00000000 00000000
Normal hardware FRU
Priority: lowest priority
Location: U7879.001.DQDFNXD-E1
Part No.: 97P5676
CCIN: 51B7
Serial number: YL1115L88111
Machine Type: 9117-570
Reference: 11007620
Hexadecimal 2-5: 003C0001 00000000 00000000 00000000
Hexadecimal 6-9: 00000000 00000000 00000000 00000000
Normal hardware FRU
Priority: lowest priority
Location: U7879.001.DQDFNXD-A2
Part No.: 53P5070
CCIN: 6B0C
Serial number:
Machine Type: 9117-570
4. devices involved in SN/location code:
A ibm ac ps:
Product Specific. (RT) ...... VINI
Flag Field ......
System Info Specific. (YL)... U7879.001.DQDFNXD-E1
Customer Card ID Number... 51B7
Serial Number...
Part Number ......
FRU Number...
Version ...... RS6K
Physical Location: U7879.001.DQDFNXD-E1
IBM Air Mover:
Product Specific. (RT) ...... VINI
Flag Field...
System Info Specific. (YL)... U7879.001.DQDFNXD-A2
Customer Card ID Number... 6B0C
FRU Number...
Version ...... RS6K
Physical Location: U7879.001.DQDFNXD-A2
5. The above information shows that a PS high-capacity power supply module and an Air Mover (fan module) are faulty. The U7879.001.DQDFNXD-E1 confirms the power module position, the first power module behind the server, the U7879.001.DQDFNXD-A2 confirms the fan position, the second fan in front of the server.
650) this. width = 650; "src =" http://www.bkjia.com/uploads/allimg/131228/0512233I5-0.png "title =" IBM-P6-560.PNG "alt =" 165621361.png"/>
Troubleshooting:
1. If it is known that the server has been down, you do not need to change the device online. You can directly power off the device.
2. Replace the power supply module first and then the fan module.
3. Power-on self-check, and then log on to HMC to view the error information. Check whether the fault is correct and start the system.
This article from the "Hello _ little strong" blog, please be sure to keep this source http://xiaozhuang.blog.51cto.com/4396589/1300180