In fact, very early plan to do in the Lazarus inside, or in the actual application of time too tight need to use the OPC of the program with Delphi change, also used. After the FPC3.0 also after lazarus1.6, its core to UTF8 comprehensive support, led to Delphi many procedures can not directly transferred to Lazarus inside. Knowing undeterred, OPC inside will use a lot of Pwidechar and olevariant this is dif
This time only under WIN7 test success, in WinXP and winserver2008 are not successful, it is recommended to install the system when the choice of win7_32-bit operating system.Siemens Insight OPC Configuration tutorialIf you do not have permission to configure OPC, this screen will appearThe correct display should appear when the configuration is complete.Configuration steps:1. Local Security policy settings
I learned a bit about. Net, exactly, but also with this. And many vc6,vb6,vb on the internet. NET but, few C # 's. Now look at this and give an example:
Test platform, is Vs2008,kepserver,opcnetapi.dll and OpcNetApi.Com.dll. Of course I also installed at the same time, Siemens Net2006 and STEP7, where Net2006 is responsible for OPC, may create some DLLs in the system, and so on, because my program to switch to a machine without Net2006 sinc
In the Nginx reverse proxy mode, the page loading is incomplete or the 502 bad gateway appears directly.
There are many cases of 502 bad Gateway, most of which are related to the setting of the Nginx timeout problem. The following is a discussion of a situation that is relatively rare but has to be noted.
Presence Environment
Nginx work in reverse proxy mode, listening to non-80 ports (this is important
All functions as the APMC configuration 1, the greatest flexibility of the software is, support UserControl, others do UserControl can be added to the configuration of 2, super-strong editing function, can be arbitrarily copied, sticky 3,FBD advanced control function 4,OPC drive by calling the OPC Foundation Opcdaauto.dll for data collection links, _ Currently can connect 1.0 and 2.0, but 2.0 data items not
A C # program written using the OPC Automation interface is running on a new machine with the following error:The component for the CLSID {28e68f9a-8d75-11d1-8dc3-3c302a000000} in the cable COM class factory failed because of the following error: 80040154 no registered Class (Exception from hresult:0x80040154 (REGDB _e_classnotreg)).Running successfully on my notebook, the registry search is as follows:The following is the interface. NET Source:namesp
Minchen OPC server core application 1.0 download: Download, details:
/* Drop table [deviceevent] */
Drop table if exists [deviceevent];
/* Device events, mainly for sending messages to devices, which will be deleted after being sent */Create Table [deviceevent] ([DeviceID] bigint not null,[Devicevalue] varchar (255) not null,Constraint [sqlite_autoindex_deviceevent_1] primary key ([DeviceID]);
/* Data [deviceevent] */
/* Drop table [deviceinfo] *
Create the following form:
The reference is as follows:
The code is as follows:
Option Explicit
Dim WithEvents ServerObj as Opcserver
Dim WithEvents Groupobj as Opcgroup
Dim Itemobj as Opcitem
Private Sub Command_start_click ()
Dim Outtext as String
On Error GoTo ErrorHandler
command_start.enabled = False
command_read.enabled = True
command_write.enabled = True
command_exit.enabled = True
Outtext = "Connect OPC server"
Set ServerObj = New opcser
Create the following form: Reference:The Code is as follows:Option ExplicitDim WithEvents ServerObj As OPCServerDim WithEvents GroupObj As OPCGroupDim ItemObj As OPCItemPrivate Sub Command_Start_Click ()Dim OutText As String On Error GoTo ErrorHandler Command_Start.Enabled = FalseCommand_Read.Enabled = TrueCommand_Write.Enabled = TrueCommand_Exit.Enabled = TrueOutText = "connecting to OPC server"Set ServerObj = New OPCServerServerObj. Connect ("XXXSER
Lazarus is now a very good editing environment, code hints and formatting functions can work better. Can even think of editing and editing part of the function is better than Delphi, but after all, the small crowd is not complete.Lazarus Development DLL with Delphi as convenient, but in the compilation process may appear in Delphi never encountered problems, reported "Xxxxxx.pas (22,1) error:undefined symbol:wsregisterxxxxxx "Information such as:The solution is to add "Interfaces" in the Applica
When developing with OPC client, you need to pay attention to memory leakage from the following aspects:
(1) All returned pointers must be released with cotaskmemfree, for example:
[Delphi] view plaincopyFunction group_tryadditems (agroupintf: iopcitemmgt; aitemcount: integer; aitems: popcitemdefarray): popcitemresultarray;VaRVerrors: presultlist;BeginResult: = nil;Verrors: = nil;If agroupintf. additems (aitemcount, psafearray (aitems), result, ve
On a machine equipped with an OPC server. DCOM is configured as follows1. Run the DCOMCNFG program on the server for DCOM configuration.2. Go to the overall default properties page of DCOM and tick "enable distributed COM on this computer" to change the default identity level to "none".3. Go to DCOM's overall default security page to confirm that default access and default boot permissions do not have everyone in the default values.If you do not remov
Program | Creates the following form asynchronously:
The reference is as follows:
The code is as follows:
Option Explicit
Option Base 1
Const writeasync_id = 1
Const readasync_id = 2
Const refreshasync_id = 3
'----------------------------------------------------------------------------
' Interface Objects
'----------------------------------------------------------------------------
Public WithEvents ServerObj as Opcserver
Public WithEvents Groupobj as Opcgroup
Dim ItemObj1 as Opcitem
Di
The program establishes the following form:
The reference is as follows:
The code is as follows:
Option Explicit
Dim WithEvents ServerObj as Opcserver
Dim WithEvents Groupobj as Opcgroup
Dim Itemobj as Opcitem
Private Sub Command_start_click ()
Dim Outtext as String
On Error GoTo ErrorHandler
command_start.enabled = False
command_read.enabled = True
command_write.enabled = True
command_exit.enabled = True
Outtext = "Connect OPC server"
Set
The gateway is used to control the flow of the process. The Gateway can consume or generate a token.
The gateway is displayed as a diamond graph with a small internal icon. The icon indicates the type of the gateway.
Basic Branch
First, use process variables to write a basic process with branches
Flowchart:
Deploym
First, real-time monitoringThe user clicks on the service instance, the system displays the list of APIs under service instance-version,The user clicks on the following two icons for an API1, API request number monitoringHorizontal axis: Time, granularity is minuteLongitudinal axis: Number of requests for accessDisplay: Number of failures (red), number of successes (green), total (yellow), "Click Red, display the list of failed logs, click the failure log, and the tree shows the local request en
-variable (Item). Variables can be grouped on demand, some groups are read only, some groups need to be refreshed 1 seconds, and some can be as long as 5 minutes, to differentiate to improve efficiency.
To be able to determine if the driver is disconnected, to provide an event that is disconnected or closed for application processing.
In short, the information is very rich, the inspiration is very large, my gateway program to a large extent,
gateways (Gateway) are also called Network Connectors, protocol converters. Gateway on the transport layer to achieve network interconnection, is the most complex network interconnection equipment, only for two high-level protocols different network interconnection. Gateways can be used both for WAN interconnection and for LAN interconnection. A gateway is a co
1, what is the gateway
According to different classification criteria, there are many kinds of gateways. The gateway in the TCP/IP protocol is the most commonly used, where we speak of "gateways" that refer to the TCP/IP protocol gateway. What is a gateway? A gateway is e
The content source of this page is from Internet, which doesn't represent Alibaba Cloud's opinion;
products and services mentioned on that page don't have any relationship with Alibaba Cloud. If the
content of the page makes you feel confusing, please write us an email, we will handle the problem
within 5 days after receiving your email.
If you find any instances of plagiarism from the community, please send an email to:
info-contact@alibabacloud.com
and provide relevant evidence. A staff member will contact you within 5 working days.